Web26. Product. LCP Dia-Meta Volar Distal Radius Plate 15 H Shaft/LT-Sterile; Indicated for fractures, osteotomies, and non-unions of the radius and other small bones. Code Information. Lot Number 9890811, Catalog ID 02.110.115S. Recalling Firm/. Manufacturer. Synthes (USA) Products LLC. 1301 Goshen Pkwy. WebThe Synthes Locking Compression Plates—Narrow and Broad, are intended for fixation of various long bones, such as the humerus, femur and tibia. They are also for use in fixation …

DePuy Synthes, Inc. Agrees to Pay $9.75 Million to Settle …

WebDevice Description: The Synthes LCP Dia-Meta Volar Distal Radius Plates provide stable fixation for radius fractures. The plates have threaded locking holes in the head of the plate that accept 2.4 mm locking screws, and dynamic compression holes combined with locking holes in the shaft of the plate which accept 3.5 mm cortex, 3.5 mm firestick on old tv https://iasbflc.org

VA-LCP Elbow - Depuy Synthes - PDF Catalogs - MedicalExpo

WebInsert Plate Bend or cut off the distal tab (optional) Instruments 391.963 Universal Bending Pliers, length 165 mm 391.931 Cutting Pliers for Plates, length 230 mm 329.916 Bending Pin for LCP Plates 3.5, with thread Bend/contour the distal tab on the plate using the Bend - ing Pins (329.916) or Bending Pliers (391.963). Alterna - Webplate as possible (Fig. 1) and tighten with the combination wrench. The handle must be horizontally aligned with the blade. Push the plate by hand into the prepared channel and … WebThe combi-holes in the LCP limited-contact plate shaft combine a dynamic compression unit (DCU) hole with a locking screw hole. The head of the plate features four locking holes that accept locking screws B 3.5 mm, cortex screws B 2.7 mm and B 3.5 mm or cancellous bone screws B 4.0 mm. The combi-holes in the plate shaft accept locking screws fire stick or google chromecast

SYNTHES LCP SURGICAL TECHNIQUE MANUAL Pdf Download ManualsLib

Category:Orthopaedic Trauma DePuy Synthes - J&J MedTech

Tags:Synthes diameta plate

Synthes diameta plate

LCP Distal Tibia Plate - synthes.hs.llnwd.net

WebThere are several criteria to consider when choosing a bone plate such as the application, whether the plate is locking or not, the geometry of the holes and the materials it is made of. Application: compression, arthrodesis or osteotomy The part of the bone concerned Side concerned (right or left) Locking plate or not Hole geometry Plate profile WebPart of the complete Synthes LCP Elbow Set LCP Olecranon Plate Variety of plates: – Left and right version – Choice of six lengths with 2, 4, 6, 8, 10 or 12 LCP combi-holes in the shaft Proximal portion of the plate with 8 locking holes allows to set a maximum number of locking screws.

Synthes diameta plate

Did you know?

WebThis site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East … Websynthes.vo.llnwd.net

WebOrdering information Sets MatrixNEURO Plates, Titanium * Strut Plate, contourable Mastoid Plate, large Temporal Mesh Plate, contourable MatrixNEURO Basic Instrument Set MatrixNEURO Standard Instrument Set incl. Insert for Mesh Plates Cranial Plate, straight, with centre space, 9 mm, 2 holes 38 ϫ 45 mm, thickness 0.6 mm, extra rigid 100 ϫ 100 ... http://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/DSEM-TRM-1214-0243-2_LR.pdf

WebVA-LCP Distal Humerus Plates The plates offer multiple screw configurations for the medial and lateral columns, and the articular block. 3 2 1 1 Medial Plate The standard medial column plate. 2 Medial Plate, with extension The extension buttresses the medial epicondyle and includes an ascending screw that stabilizes the medial column. 5 4 3 … WebIndications The 3.5 mm LCP Extra-articular Distal Humerus Plate ® is indicated for fractures of the distal humerus. 3.5 mm LCP Extra-articular Distal Humerus Plate Surgical Technique DePuy Synthes ®... Page 7: Preparation Complete the preoperative radiographic assessment and prepare the preoperative plan.

WebSenior Product Development Engineer. DePuy Synthes. Oct 2024 - Present1 year 5 months. Raynham, Massachusetts, United States. -Integral team member for the Conduit Lateral …

WebThe Synthes VA Locking Tarsal Plates are intended for the fixation of fractures, osteotomies, nonunions, replantations, and fusions of the Cuboid and Navicular bones, particularly in osteopenic bone. The Mesh Plate, part of the Variable Angle LCP Forefoot / Midfoot System 2.4/2.7, is indicated for fractures, ethylene glycol 30%WebJan 20, 2024 · Medical device manufacturer DePuy Synthes, Inc. (DePuy), a subsidiary of Johnson & Johnson, has agreed to pay $9.75 million to resolve allegations it violated the … fire stick or chromecastWebApr 13, 2010 · In the photo below you see a new Dynaplate: The Dynaplate is made of what is known as sintered bronze, think of the plate as a metallic 'sponge". Looked at under a … fire stick optimizing storageWebsynthes compact distal radius synthes diameta plate Create this form in 5 minutes! Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms. Get Form How to create an eSignature for the synthes va elbow inventory control form fire stick optimizing system storageWebFeb 2, 2013 · The LCP Dia - Meta ( Dia physeal– Meta physeal) Volar Distal Radius Plate is an anatomic plate designed for fractures of the distal radius that extend into the radial shaft. The plate design combines 2.4 mm locking technology in the distal radius with 3.5 mm LCP technology in the radial shaft. ethylene glycol 35%WebMar 29, 2024 · The LCP Dia-Meta (DiaphysealMetaphyseal) Volar Distal RadiusPlate is an anatomic plate designedfor fractures of the distal radiusthat extend into the radial shaft. The plate design combines 2.4 mmlocking technology in the distalradius with 3.5 mm LCP technologyin the radial shaft. ethylene glycol abghttp://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/DSEM-TRM-0815-0473-1_LR.pdf fire stick on smart tv